CADS Logo

Back to previous page

 

SMART Modeller EPW Tackles a Portal Frame with Ease

 12 Apr 2006

Cech Logo

Chládkova 22c
616 00 Brno
Czech republic

Tel.: +420 541215799
Fax: +420 541215799
Contact: M. Cech Jiri Jiri
Email:

 

Technical Data
span 39,90 m
length 63,0 m
heigth 11,0 m
weight 58,8 ton

Program
SCIA ESA PT version 5.0 Modules
Linear static analysis of frame 3D
Stress check CSN 731401 code
Parametres
Productivity toolbox
Intelligent document

 

Winter Stadium

 

Technical Solution
The project regards a steel, one aisled, hall with an arched roof. There are 6 bearing frames in the longitudinal module (9,00 m).
The front columns are symmetrical ones with an in-between distance of 4,50 m. The eaves are situated in the height (+8,725 m).
The frame cross bar has a polygonal shape and the rise of the arch is 2,125 m. The structure is seated on level -0,30 m, it is fastened by anchoring bolts. The static system of the structure is a hinged supported arch frame. The wind bracing consists of 2 crossed diagonals in penultimate bay. The steel tube bar is used on the level +3,350 m to decrease the columns buckling lengths. The bearing structure consists of welded I profile elements, all bolted together. The steel grade S355 is used. The flange of the I profiles has a thickness of 6 mm and is equipped with stiffeners. The webs of the I profiles have different thicknesses, that is 10 or 20 mms, and different widths according to the inner forces course. METSEC system profiles are used for the secondary structure (purlins and spandrel beams) as well as thinwalled bend profiles.

Back to previous page

 

 

Autodesk Authorised Developer
Microsoft Certified Partner


© 2008 CADS All rights reserved.

UK: Computer and Design Services Ltd
; Tel: +44 (0)1202 603031

India: CADS Software India (P) Ltd
; Tel: +91 (0)44-28233681/2/3/4

Dubai:
CADS International Computer System Design
; Tel: 00971 4 3517330

 
Powered by Intergage